Inspection items
9 PRECAUTIONS FOR MAINTENANCE AND INSPECTION
The inverter is a static unit mainly consisting of semiconductor devices. Daily inspection must be performed to prevent any
fault from occurring due to the adverse effects of the operating environment, such as temperature, humidity, dust, dirt and
vibration, changes in the parts with time, service life, and other factors.
Precautions for maintenance and inspection
For some short time after the power is switched OFF, a high voltage remains in the smoothing capacitor. When accessing the
inverter for inspection, wait for at least 10 minutes after the power supply has been switched OFF, and then make sure that
the voltage across the main circuit terminals P/+ and N/- of the inverter is not more than 30VDC using a tester, etc.
If "EV" is displayed on the operation panel with FR-E7DS mounted, turn off the 24V external power supply before an
inspection.
9.1 Inspection items

It is recommended to install a device to monitor voltage for checking the power supply voltage to the inverter.

One to two years of periodic inspection cycle is recommended. However, it differs according to the installation environment.
For a periodic inspection, contact your sales representative. 
REMARKS
For maintenance/inspection and parts life, also refer to 
 the Instruction Manual (Applied).
Area of 
Inspection
Inspection 
Item
Description
Interval
Corrective Action at Alarm 
Occurrence
Customer's 
Check
Daily
Periodic

General
Surrounding 
environment
Check the surrounding air temperature, 
humidity, dirt, corrosive gas, oil mist, etc.
Improve environment
Overall unit
Check for unusual vibration and noise.
Check alarm location and retighten
Power supply 
voltage
Check that the main circuit voltages are normal. 
Inspect the power supply
Main circuit
General
(1) Check with megger (across main circuit 
terminals and earth (ground) terminal).
Contact the manufacturer
(2) Check for loose screws and bolts.
Retighten
(3) Check for overheat traces on the parts.
Contact the manufacturer
(4) Check for stain.
Clean
Conductors, 
cables
(1) Check conductors for distortion.
(2) Check cable sheaths for breakage and 
deterioration (crack, discoloration, etc.).
Contact the manufacturer
Contact the manufacturer
Terminal 
block
Check for damage.
Stop the device and contact the 
manufacturer.
Smoothing 
aluminum 
electrolytic 
capacitor
(1) Check for liquid leakage.
Contact the manufacturer
(2) Check for safety valve projection and bulge.
Contact the manufacturer
(3) Visual check and judge by the life check of 
the main circuit capacitor (
Refer to 
Chapter 4 of the Instruction Manual (Applied).)
Relay
Check that the operation is normal and no 
chatter is heard.
Contact the manufacturer
Control 
circuit,
Protective 
circuit
Operation 
check
(1) Check that the output voltages across phases 
with the inverter operated alone is balanced.
Contact the manufacturer
(2) Check that no fault is found in protective and 
display circuits in a sequence protective 
operation test.
Contact the manufacturer
P
a
rt
s ch
eck
Overall
(1) Check for unusual odor and discoloration.
Stop the device and contact the 
manufacturer.
(2) Check for serious rust development.
Contact the manufacturer
Aluminum 
electrolytic 
capacitor
(1) Check for liquid leakage in a capacitor and 
deformation trace.
Contact the manufacturer
(2) Visual check and judge by the life check of 
the main circuit capacitor (
Refer to 
Chapter 4 of the Instruction Manual (Applied).)
Cooling 
system
Cooling fan
(1) Check for unusual vibration and noise.
Replace the fan
(2) Check for loose screws and bolts.
Fix with the fan cover fixing screws
(3) Check for stain.
Clean
Heatsink
(1) Check for clogging.
Clean
(2) Check for stain.
Clean
Display
Indication
(1) Check that display is normal.
Contact the manufacturer
(2) Check for stain.
Clean
Meter
Check that reading is normal.
Stop the device and contact the 
manufacturer.
Load motor
Operation 
check
Check for vibration and abnormal increase in 
operation noise.
Stop the device and contact the 
manufacturer.