Control circuit
33
2
2.6
Control circuit
2.6.1
Details on the control circuit terminals of the 
inverter
The input signal function of the terminals in 
 can be selected by setting Pr.178 to Pr.196 (I/O terminal function 
selection).
For the parameter details, refer to the FR-A800 Instruction Manual (Detailed).
Input signal
Ty
p
e
Terminal
Symbol
Terminal name
Terminal function description
Rate Specification
Cont
ac
t input
STF
Forward rotation start
Turn ON the STF signal to start forward 
rotation and turn it OFF to stop.
When the STF and 
STR signals are turned 
ON simultaneously,  the 
stop command is given.
Input resistance 
4.7 k
Voltage when 
contacts are open: 21 
to 27 VDC
When contacts are 
short-circuited: 4 to 6 
mADC
STR
Reverse rotation start
Turn ON the STR signal to start reverse 
rotation and turn it OFF to stop.
STOP
Start self-holding 
selection
Turn ON the STOP signal to self-hold the start signal.
RH
RM
RL
Multi-speed selection
Multi-speed can be selected according to the combination of RH, RM 
and RL signals.
JOG
Jog mode selection
Turn ON the JOG signal to enable JOG operation (initial setting) and 
turn ON the start signal (STF or STR) to start JOG operation.
Pulse train input
Terminal JOG is also used as the pulse train input terminal. To use as 
a pulse train input terminal, change the Pr.291 setting.
(maximum input pulse: 100k pulses/s)
Input resistance 2 k
When contacts are 
short-circuited: 8 to 13 
mADC
RT
Second function 
selection
Turn ON the RT signal to enable the second function.
When the second function such as "second torque boost" and "second 
V/F (base frequency)" is set, turning ON the RT signal enables the 
selected function.
Input resistance 
4.7 k
Voltage when 
contacts are open: 21 
to 27 VDC
When contacts are 
short-circuited: 4 to 6 
mADC
MRS
(X10)
Output stop
(Inverter operation 
enable)
Connect to the terminal RDA of the converter unit (FR-CC2). When 
the RDA signal is turned OFF, the inverter output is shut off.
The X10 signal (NC contact) is assigned to the terminal MRS in the 
initial setting. Use Pr.599 to change the specification to NO contact.
RES
Reset
Use this signal to reset a fault output provided when a protective 
function is activated. Turn ON the RES signal for 0.1s or longer, then 
turn it OFF.
In the initial setting, reset is always enabled. By setting Pr.75, reset 
can be enabled only at an inverter fault occurrence. The inverter 
recovers about 1s after the reset is released.
AU
Terminal 4 input 
selection
The terminal 4 function is available only when the AU signal is ON
Turning ON the AU signal disables the terminal 2 function.
CS
Selection of 
automatic restart 
after instantaneous 
power failure
When the CS signal is left ON, the inverter restarts automatically at 
power restoration. Note that restart setting is necessary for this 
operation. In the initial setting, a restart is disabled.
SD
Contact input 
common (sink)
Common terminal for contact input terminal (sink logic) and terminal 
FM 
———
External transistor 
common (source)
Connect this terminal to the power supply common terminal of a 
transistor output (open collector output) device, such as a 
programmable controller, in the source logic to avoid malfunction by 
undesirable current.
24 VDC power supply 
common
Common terminal for the 24 VDC power supply (terminal PC, terminal 
+24)
Isolated from terminals 5 and SE.
PC
External transistor 
common (sink)
Connect this terminal to the power supply common terminal of a 
transistor output (open collector output) device, such as a 
programmable controller, in the source logic to avoid malfunction by 
undesirable current.
Power supply voltage 
range 19.2 to 28.8 
VDC
Permissible load 
current 100 mA
Contact input 
common (source)
Common terminal for contact input terminal (source logic).
24 VDC power supply 
common
Can be used as a 24 VDC 0.1 A power supply.