Control circuit
40
2.6.4
Wiring of inverter control circuit
Control circuit terminal layout

This terminal operates as the terminal FM for the FM type, and as the terminal CA for the CA type.

Represents the terminal STOP.

The X10 signal is assigned in the initial setting.

No signal is assigned in the initial setting.
Wiring method
 • Power supply connection
For the control circuit wiring, strip off the sheath of a cable, and use it with a blade terminal. For a single wire, strip off the 
sheath of the wire and apply directly.
Insert the blade terminal or the single wire into a socket of the terminal.
(1) Strip off the sheath for the below length. If the length of the sheath peeled is too long, a short circuit may occur with
neighboring wires. If the length is too short, wires might come off.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it.
(2) Crimp the blade terminal.
Insert wires to a blade terminal, and check that the wires come out for about 0 to 0.5 mm from a sleeve.
Check the condition of the blade terminal after crimping. Do not use a blade terminal of which the crimping is inappropriate, 
or the face is damaged.
 • Blade terminals commercially available (as of February 2012)
Phoenix Contact Co., Ltd.
Cable sheath stripping length
Cable gauge 
(mm
2
)
Blade terminal model
Crimping tool 
name
With insulation sleeve
Without insulation sleeve
For UL wire 
0.3
AI 0, 5-10WH
-
-
CRIMPFOX 6
0.5
AI 0, 5-10WH
-
AI 0, 5-10WH-GB
0.75
AI 0, 75-10GY
A 0, 75-10
AI 0, 75-10GY-GB
1
AI 1-10RD
A 1-10
AI 1-10RD/1000GB
1.25, 1.5
AI 1, 5-10BK
A 1, 5-10
AI 1, 5-10BK/1000GB
0.75 (for two wires)
AI-TWIN 2 
 0, 75-10GY
-
-

A blade terminal with an insulation sleeve compatible with the MTW wire which has a thick wire insulation.

Applicable for the terminals A1, B1, C1, A2, B2, and C2 only.
AM
2
5
4
1 F/C +24 SD
SD
S1 S2 PC
A1
B1
C1
A2
B2
C2
SIC
So SOC
5 10E 10 SE SE
SU
RUN
IPF OL FU
PC RL RM RH RT AU
SD SD
CS
STP MRS
(X10)
∗3
RES
STF STR JOG
∗1
∗2
∗4
10 mm
Crumpled tip
Wires are not inserted
into the sleeve
Unstranded
wires
Damaged
Wire
W
ire
Sleeve
Sl
ee
ve
0 to 0.5mm (0.02 inch)
0 t
o 0
.5m
(0
.02
 in
ch
)