Multiquip GA-6RZR2 ユーザーズマニュアル

ページ / 52
GA-6RZR2 A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #5  (09/16/05) — PAGE 9
GA-6RZR2— GENERAL INFORMATION
GA-6RZR2 FAMILIARIZATION
Generator
The Multiquip Model GA-6RZR2 generator has been designed
as a portable lightweight power source for 60 Hz (single-
phase) vibrators, lighting facilities, power tools, submersible
pumps and other industrial and construction machinery.
This generator is powered by a ROBIN gasoline engine.  The
alternator, a brushless revolving-field type, is permanently
aligned to the  engine through rigid coupling.
The  generator is mounted on rubber vibration isolators that
have a steel base backplate which is attached to the
protective steel pipe carrying frame. The protective carrying
frame is made of steel tubing and fully wraps around the
generator to protect against damage.
This portable generator is supplied with a electrical 
control
box. To reduce vibration caused by the engine, the  control
box is also placed on rubber isolators.
Control Box
The control box has the following: (all outputs are 60 Hz,
single phase)
z One 120V output  receptacle.
z One 240V output  receptacle.
z One 120V output  receptacle (GFI protected).
z One main 21 amp circuit breaker.
z AC Voltmeter
z Idle Control Switch
z Full Power Switch
z Operation Switch
Excitation System
All GA-series generators use a magnet attached to a flywheel
to produce AC voltage from a lamp coil beneath the flywheel.
As the magnet passes the coil it produces approximately
19-22 AC volts.
This voltage (19-22 VAC) is then sent to the control box that
contains three rectifying diodes:
z Excitation (diode 1)
z Battery (diode 2)
z Slow Down (diode 3)
The AC voltage will pass through the excitation diode that
converts the voltage to DC power.
This DC power is then sent to the excitation windings housed
within the main windings commonly called the "stator".
This voltage is then transferred into the rotor through
induction. The rotor contains two diodes within it which rectify
the DC voltage and send it out through the main windings,
as AC voltage.
Engine
The four-cycle air-cooled ROBIN gasoline  engine is designed
to meet every performance requirement of this generator.
Reference Table 1, page 8  for engine specifications.
Figure 1 (page 10) shows the basic controls and indicators
for the GA-6RZR2 generator.
WARNING:
Before connecting this generator to
any building’s electrical system, a
licensed electrician must install an
isolation (transfer) switch.
Serious injury or death may result
without this transfer switch.
NOTE
In keeping with Multiquip's policy of
constantly improving its products, the
specifications quoted herein are subject
to change without prior notice.