Mitsubishi Electronics MDS-D-SPJ3 ユーザーズマニュアル

ページ / 284
Appendix 6 Instruction Manual for Compliance with UL/c-UL 
MITSUBISHI CNC
Appendix 6 - 10
Appendix 6-3 AC Servo/Spindle System Connection
Appendix 6-3-1 MDS-D/DH/DM-Vx/SP Series
Appendix 6-3-2 MDS-D-SVJ3/SPJ3 Series
CN1B
 
CN1A
 
CN4
 
CN9
 
CN3L
 
CN2L
CN3M
 
CN23A
 
CN2M
 
CN1B
 
CN1A
 
CN4
 
CN9
 
L+/L
L11/L21
 
CN4
 
 
CB 
MU/MV/MW
 
L1/L2/L3
 
U/V/W
 
LU/LV/LW
 
CN9
 
MC
CB 
CN3L
 
CN2L
 
CN3M
 
CN2M
 
MDS-D/DH/DM-V1/V2/V3
MDS-D/DH-SP
MDS-D/DH-CV
CN3S
CN2S
SU/SV/SW
CN23B
(MCCB)
Series
Series
Series
 
Refer to specification manual 
IB-1500003 or IB-1500011
or IB-1500875 or IB-1500891.
 
 
3 phase
DH Series: 380 
㨪 480VAC
D/DM Series: 200 
㨪 230VAC
Battery Unit
Note: It recommends installing.
Contactor
 
Fuse 
or 
Circuit Breaker
 
 
 
Servo Motor  
Spindle Motor
 
Encoder
 
FAN
 
Servo Motor  
 
AC Reactor
 
Encoder and
 
Thermal Protection  
From NC
External Emergency Stop
Regarding the connection of NC, 
see the CNC manual book.
Enclosure Side
Machine Side
Servo Motor
Encoder
Encoder
CN1B
 
CN1A
 
CN2
CNP2
 
 
CN9
CNP1
CNP3
MC
CB
CN3
CN8
MDS-D-SVJ3
MDS-D-SPJ3
From NC
External 
Emergency Stop
Enclosure Side
Machine Side
Servo/Spindle Motor
Encoder
 
Contactor
Note: It recommends installing.
Input
Resistor
3 phases
200 ~ 230Vac
CN8
(Only SVJ3S, 
SPJ3S)
Fuse 
or 
Circuit Breaker
Regarding the connection of NC, 
see the CNC manual book.
Refer to specification manual 
 IB-1500158.
Series
Series