Mitsubishi Electronics MDS-R ユーザーズマニュアル

ページ / 362
 
5. Peripheral Devices 
 
 
 
 
 
5 - 8
5-5  Noise filter 
 
(1) Selection 
Use an EMC noise filter if the noise conducted to the power line must be reduced. Select an EMC 
noise filter taking the drive unit's input rated voltage and input rated current into consideration. 
 
(2)  Noise filter mounting position 
Install the noise filter to the drive unit’s power input as the diagram below indicates. 
 
 
 
Drive unit
 
MDS-R-V1/V2 
 
Noise filter
 
T
S
R
Breaker 
Power 
supply 
Power  
distribution panel 
 
Contactor
 
 
(Note)  The noise filter must be prepared by the user. 
 
 
 
Recommended devices: 
Densei-lambda 
MX13 Series 
 
Soshin Electric 
HF3000C-TM Series 
 
 
 
Contact: 
Densei-lambda Co., Ltd.
TEL0120-507039 
 
Soshin Electric Co., Ltd. TEL03-3775-9112(+81-3-3775-9112) 
http://www.soshin.co.jp 
 
(Note)  The above devices may be changed at the manufacturer's discretion. 