Mitsubishi Electronics MDS-R ユーザーズマニュアル

ページ / 362
 
4. Dedicated Options 
 
 
 
 
 
4 - 2
4-1  Regenerative option 
 
For the regenerative option, always select a regenerative resistor unit or regenerative resistor in the 
correct combination for each servo drive unit. Refer to "Appendix 2-2 Selecting the regenerative 
resistor" for details on selecting the regenerative option. 
The regenerative resistor generates heats, so wire and install the unit while taking care to safety. When 
using the regenerative resistor, make sure that flammable matters, such as cables, do not contact the 
resistor, and provide a cover on the machine so that dust or oil does not accumulate on the resistor and 
ignite. 
 
List of regenerative option correspondence 
 
Regenerative 
resistor type 
(Japan 
Resistor) 
GZG80 
W26 
OHMJ 
GZG200 
W26 
OHMJ 
GZG300 
W20 
OHMJ 
GZG400
W13 
OHMJ
GZG400
W8 
OHMJ
GZG200
W120 
OHMJ 
3 units 
connected 
in parallel
GZG200
W39 
OHMJ 
3 units 
connected 
in parallel
GZG300
W39 
OHMJ 
3 units 
connected 
in parallel
GZG200 
W20 
OHMJ 
3 units 
connected 
in parallel 
GZG300 
W20 
OHMJ 
3 units 
connected 
in parallel
GRZG400-2
OHMJ 
4 units 
connected 
in serial 
Regenerative 
resistor unit 
type 
 
 
 
 
 
MR-RB32 MR-RB30 MR-RB50 MR-RB31 MR-RB51 MR-RB65
Regenerative 
capacity 
40W 100W 150W 200W
200W
300W  300W 500W 300W 500W 800W 
Resistance 
value 
26Ω 
26
 20 13
8
 40 13 13 6.7 6.7 
8
 
MDS-R-V1-20 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-40 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-60 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V1-80 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-2020 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-4040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-6040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-6060 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8040 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8060 
 
 
 
 
 
 
 
 
 
 
 
MDS-R-V2-8080 
 
 
 
 
 
 
 
 
 
 
 
 
Note: Types indicated with a 
 cannot be used when driving the HF353 motor. 
 
Manufacturer: Japan Resistor