Mitsubishi Electronics E70 ユーザーズマニュアル

ページ / 214
4 Connection
MITSUBISHI CNC
98
4.4 Connection of Remote I/O Unit
This chapter describes the connection of the remote I/O unit and machine control signals. 
4.4.1 Connection and Station No. Setting on Remote I/O Unit
When connecting directly to the control unit
(Note)
A remote I/O unit has one or two rotary switch(es) for unit No. setting, which links the device Nos. (with X/
Y). The rotary switch setting is as follows, from "0" to "7".
Station 
No.
Rotary switch
1
0
2
1
3
2
4
3
5
4
6
5
7
6
8
7
FCUA-R211
RIO1
0
7
FCUA-DX1x1
1ch
Station No.1 - 8
Remote I/O unit
Control unit
Remote I/O
Max. 8 channels
Max. input: 256 points (X000 to X0FF)