Mitsubishi Electronics E70 ユーザーズマニュアル

ページ / 214
E70 Series Connection Manual
Appendix 1.27 G011 Cable
145
Appendix 1.27 G011 Cable
Max. cable length:  0.5m
Application:  Connection between NC unit and operation panel I/O unit
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil 
tape to GND plate of the connector. 
[CG71]
Connector: 10126-3000VE 
Case:  10326-52F0-008 
Recommended manufacturer: 3M
Wire material: UL20276 AWG28×13P 
Recommended manufacturer: 
Toyokuni Electric Cable
G011
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
26
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
26
GND
GND
5V
5V
5V
3.3V
GND
GND
KBCS0*
KBCS1*
KBCS2*
KBAD0
KBAD1
KBAD2
KBD0
KBD1
KBD2
KBD3
KBRES*
RDYOUT*
BUZOUT*
3.3V
TXRX3
TXRX3*
SCAN36
SCAN36
FG
FG
Case frame
Case frame