Mentor v8.6_4 ユーザーズマニュアル
Command Dictionary
Set Shadow Check
FastScan and FlexTest Reference Manual, V8.6_4
2-575
Set Shadow Check
Tools Supported: FastScan
Scope: All modes.
Usage
SET SHadow Check OFf | ON
Description
Specifies whether FastScan will identify sequential elements as a “shadow”
element during scan chain tracing.
element during scan chain tracing.
You can use the Set Shadow Check command to disable the checking and avoid
corresponding error messages. This will prevent identification of any non-scan
sequential element as a shadow element.
corresponding error messages. This will prevent identification of any non-scan
sequential element as a shadow element.
Arguments
•
OFf
A literal that disables shadow checking.
•
ON
A literal that enables shadow checking. This is the initial state upon invocation
of FastScan.
of FastScan.
Related Commands