4  Software Operation
MIX 56 User Manual
4-44
Telect, Inc. 122188-10 A0
Step
Action
1.
From the Directory screen, type 8 to select Alarm Thresholds and 
press Enter.
The Alarm Thresholds screen appears.
  
2.
To set an alarm threshold, tab to the threshold field (ex. Low Speed 
AIS Alarm On), type the number of seconds the condition must ex-
ist before triggering an alarm (Alarm On) or the number of seconds 
the condition must be absent to turn off the alarm (Alarm Off), and 
then press Enter.
3.
To enable redundancy switching, tab to the [Clear Lock] button and 
press Enter. You can tab to this button only when redundancy 
switching is locked.
The Redundancy Switch Status field displays “Normal” if not 
locked, or displays “Locked Out” if locked. The [Clear Lock] but-
ton is only enabled if Status is “Locked Out”.
Viewing Events
Any occurrence in the MIX 56 system, whether initiated by a user or by the 
system, is an event. You can view events in the Event Log, a screen that 
displays the last 99 events.
MIX 56 by Telect                      MIX 56                  Directory (Ctrl+D)
                                                                        Help (?)
                                Alarm Thresholds (in seconds)
                                ----------------
                     Low Speed                      High Speed
                     ---------                      ----------
                  Alarm On  Alarm Off           Alarm On  Alarm Off
                  --------  ---------           --------  ---------
             AIS: 999       003            AIS: 002       003
             LOS: 002       003            RAI: 002       003
                                           LOS: 002       003
                                           OOF: 002       003
                      Alarm On                      Alarm On
                      --------                      --------
           ES-15 min: 065                ES-15 min: 025
           ES-24  hr: 648                ES-24  hr: 250
          SES-15 min: 010               SES-15 min: 004
          SES-24  hr: 100               SES-24  hr: 040
                       Redundancy Switch Status: Normal
                                                 [Clear Lock]