I-Data 812-1x MIO ユーザーズマニュアル

ページ / 55
ida 812-1x MIO Operator’s Guide
Errors and Recovery
-30-
6. Errors and Recovery
6.1. Error Messages in MIO front panel
The 80_service (01XX) error message will be displayed in the
MIO front panel if the following error situations occur:
Recovery attempt can be made as follows:
• 
Turn power off for 10 seconds and then on again. If the
problem persists, contact technical assistance.
DESCRIPTION
XX CAUSED BY
RECOVERY
Firmware check
sum error
61
Comes at power on after
interrupted download of
firmware
Download
firmware again
Flash prom error
71
Flash prom used by
firmware damaged
Install new flash
prom
Flash prom error
72
Flash prom used by
firmware damaged
Install new flash
prom
Line interface RAM
ERROR
81
Hardware error
Wrong data in self
test
82
Hardware error
Wrong word in self
test
83
Hardware error
Response missing
from Twinax
interface
84
Hardware error
Wrong interrupt
from Twinax
interface
85
Hardware error
No test response
from Twinax
interface
86
Hardware error
Invalid test
response
87
Hardware error
Nothing received in
self test
8A Hardware error
Forced download
8B Hardware error
End of flash
program
8C Download of firmware
finished successfully
Error in HEX data
8D An error has occurred
when firmware was
Power OFF and
ON and download