6.4.2    Batch change of specified devices between normally open contacts and normally closed contacts 
This section explains how to change the normally open contacts of the specified 
devices to the normally closed contact and vice versa in batch. 
 
1) Click [Find/Replace] 
→ [Change Open/Close 
Contact]. 
2)  The Find/Replace dialog box is displayed. 
Enter "X4" in the "Replace Device" list box. 
 
3)  After the setting is completed, click the 
 All Replace   button. 
3) Click!
1) Click!
2) Enter "X4"!
(Before)
0
X6
Y50
Y50
T0
Y54
K1500
T1
K30
BCD TO K4Y30
X1
X4
M10
X6
Y54
Y54
T1
X6
4
13
17
(After)
0
X6
Y50
Y50
T0
Y54
K1500
T1
K30
BCD TO K4Y30
X1
X4
M10
X6
Y54
Y54
T1
X6
4
13
17
4)  Confirm that the normally open contact is 
changed to the normally closed contact and 
vice versa. 
 
NOTE 
 
Before exercising section 6.5 after this section, write the program in the 
personal computer to the CPU. 
For the write operation, refer to section 2.7.