7.5.5    Exercise with the demonstration machine 
(1) Sequence 
program 
The sequence program executes a sampling processing on analog voltages 
input through CH1 of Q64AD, and then converts the analog values to digital 
values. 
Set the start XY of Q64AD to 80 as explained before. 
 
Project name 
Q64AD 
Program name 
MAIN 
 
X3
0
K4Y50
D10
BCD
Displays digital conversion value
of CH1 on LED
X8E
9
A/D conversion completed flag
END
K0
D10
>=
X80
A/D module READY
 
 
X80:  Module READY signal 
X8E:  A/D conversion completed flag 
At power-on or reset of a programmable controller CPU, this flag turns on if 
A/D conversion is ready to be executed. A/D conversion is executed once this 
flag turned on. 
 
(2)  Operation of the demonstration machine 
Stop the CPU and click 
  on the toolbar. 
The Online Data Operation dialog box is displayed. Click the 
 Parameter + Program    button, then click the   Execute    button to write data 
to the CPU. After that, activate the CPU and check the following items. 
 
(a)  Turn on X3, and change input voltages for an A/D converter module with 
the volume on the demonstration machine. 
Analog values that have been input to the channel 1 (CH1) of Q64AD are 
stored to the buffer memory (in digital value). With the auto refresh settings, 
the QCPU reads the stored digital values and stores them in its data 
register D10. 
(b)  Whenever an analog value is "-1" or smaller, 0 is set. 
(c)  The digital values are displayed on the digital display (Y50 to Y5F).