Mitsubishi Electronics 13JW55 ユーザーズマニュアル

ページ / 350
 
 
App. - 36
 
 
 
Appendix 4.23    Application example using index Z 
(1)  The number of manufactured products is counted every day in one month cycle, 
and the resulting number is stored to the corresponding register of the date (D1 
to D31). 
(2)  The planned number of products to be manufactured is inputted with the 
external digital switch. Production stops when this number is accomplished. 
(3)  The date is also specified with the external digital switch. 
(4)  The accumulated number of products manufactured in the current month as 
well as the number of manufactured products on the current day is displayed to 
exterior. 
 
K2X20
K4X30
X02
Input 
module
Output 
module
K2Y58
K4Y40
K4Y60
Date display
Manufactured number 
on current day
Accumulated number
Date
Planned number 
of products
Count value
3
0
0
1
8
0
3
0
0
1
8
0
3
7
8
2
 
 
The number of products manufactured on the current day is counted by C5. 
The accumulated number of products manufactured is counted by C6. 
The date is entered in the index Z to indirectly specify the data register 
corresponding to the date using D0Z0. 
When Z0 is 30, D0Z0 becomes 0 + 30, specifying D30. 
 
[Device/Buffer Memory Batch Monitor screen] 
Accumulated number
Planed number of products
Date
Stores the resulting 
number of each day 
ranging from 1 to 31 
in D1 to D31.
 
 
Manufacturing results of each day ranging from 1 to 31 are stored in D1 to D31, 
which are available as production data.