Mitsumi electronic NZ2GF-ETB ユーザーズマニュアル

ページ / 246
224
Appendix 8
EMC and Low Voltage Directives
Compliance to the EMC Directive, which is one of the EU Directives, has been a legal obligation for the products sold 
in European countries since 1996 as well as the Low Voltage Directive since 1997.
Manufacturers who recognize their products are compliant to the EMC and Low Voltage Directives are required to 
attach a "CE mark" on their products.
(1) Sales representative in EU member states
Sales representative in EU member states is shown below.
Name: Mitsubishi Electric Europe BV
Address: Gothaer Strasse 8, 40880 Ratingen, Germany
Appendix 8.1
Measures to comply with the EMC Directive
The EMC Directive specifies that "products placed on the market must be so constructed that they do not cause 
excessive electromagnetic interference (emissions) and are not unduly affected by electromagnetic interference 
(immunity)". This section summarizes the precautions on compliance with the EMC Directive of the machinery 
constructed with the Ethernet adapter module.
These precautions are based on the requirements and the standards of the regulation, however, it does not guarantee 
that the entire machinery constructed according to the descriptions will comply with the above-mentioned directives.
Machine manufacturers are required to determine the method and judgment for complying with the EMC Directive at 
their discretion.
(1) EMC Directive related standards
(a) Emission requirements
*1
QP: Quasi-peak value, Mean: Average value 
*2
The Ethernet adapter module is an open-type device (a device designed to be housed inside other equipment) and must 
be installed inside a conductive control panel. The corresponding tests were conducted with the Ethernet adapter 
module installed inside a control panel.
Specification
Test item
Test details
Standard value
EN61131-2: 2007
CISPR16-2-3
Radiated emission
*2
Radio waves from the product 
are measured.
• 30M-230MHz
QP: 40dBµV/m (10m in measurement range)
*1
• 230M-1000MHz
QP: 47dBµV/m (10m in measurement range)
CISPR16-2-1,
CISPR16-1-2
Conducted emission
*2
Noise from the product to the 
power line is measured.
• 150k-500kHz
QP: 79dB, Mean: 66dB
*1
• 500k-30MHz
QP: 73dB, Mean: 60dB