Power in connection
The.AdderView.CATx.unit.is.
supplied.with.a.single.30W.power.
adapter.which.is.sufficient.to.supply.
any.configuration.of.the.unit..The.
AdderView.CATx.IP.unit.has.two.
power.input.sockets.to.allow.an.
auxiliary.(redundant).power.adapter.
to.be.connected..There.is.no.on/off.
switch.on.the.unit,.so.operation.
begins.as.soon.as.a.power.adapter.
is.connected.
Note: AdderView CATx units require a heavy duty power adapter at either or 
both power input connectors. Use only the adapter supplied with the unit or 
available under Adder part number: PSU-IEC-5V6A. Do not use the standard 
10W adapters that are supplied with other Adder products, such as the X100. 
To connect the power supply
1. Attach.the.output.lead.from.the.power.adapter.to.the.
MAIN PWR IN
.socket.
on.the.rear.panel.of.the.AdderView.CATx.
2. Connect.the.IEC.connector.of.the.supplied.country-specific.power.lead.to.
the.socket.of.the.power.adapter.
3. Connect.the.power.lead.to.a.nearby.main.supply.socket.
4. Repeat.steps.1.to.3.for.the.auxiliary.power.adapter.(using.the.
AUX PWR IN
.
socket),.if.a.backup.supply.is.required.
Note: Both the AdderView CATx and its power supply generate heat when in 
operation and will become warm to the touch. Do not enclose them or place 
them locations where air cannot circulate to cool the equipment. Do not operate 
the equipment in ambient temperatures exceeding 40 degrees Centigrade. Do 
not place the products in contact with equipment whose surface temperature 
exceeds 40 degrees Centigrade. Using two power supplies will ensure that each 
power supply takes less load and run at a correspondingly cooler temperature.
AdderView CATx 
rear panel
output lead from 
power adapter