Extron electronic DTPTEU232 ユーザーズマニュアル

ページ / 40
 
DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Installation and Operation
13
 
VGA Connector Wiring
The 15-pin HD (VGA) universal analog input port accepts RGB (RGBHV, RGBS, RGsB) and 
component video. Figure 10 shows the pinout for each format type on the connector.
Pin
RGBHV
1
Red
Green
R-Y
Y
Red return
R-Y return
Green return
Y return
Blue return
B-Y return
NC
NC
Blue
B-Y
RGBS
Component
2
Red
Green
NC
6
Red return
7
Green return
8
Blue return
3
Blue
1
5
11
15
4, 5
Pin
RGBHV
RGBS
Component
9
10
14
15
11
12
13
NC
Ground
V sync
NC
H sync
NC
Ground
NC
NC
NC
NC
C sync
NC
NC
NC
NC
NC
NC
NC
NC
NC
Figure 10. 
VGA Connector
TP Cable Termination and Recommendations
Figure 11 details the 
TIA/EIA T 568B wiring standard. Use this standard to terminate the 
DTP cable with RJ-45 connectors.
5
Pin
1
2
3
6
7
8
4
Side
1 2 3 4 5 6 7 8
Insert
Twisted
Pair Wires
Pins:
RJ-45
Connector
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568 B
Figure 11. 
TP Cable Termination
NOTE:  Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 
cable to link the switching transmitter and receiver. The DTP T EU and DTP T MK units 
do not work properly with these cables.
Supported cables
The DTP T EU and DTP T MK units are compatible with shielded twisted pair (STP) and 
unshielded twisted pair (U/UTP) cable. However, Extron strongly recommends that you use 
STP cable to achieve best performance.
ATTENTION:
• 
To ensure FCC Class A and CE compliance, STP cables and STP connectors are 
required.
• 
Afin de s’assurer de la compatibilité entre FCC Classe A et CE, les câbles STP et 
les connecteurs STP sont nécessaires.