Extron electronic DTPTEU232 ユーザーズマニュアル

ページ / 40
 
DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Remote Control
20
 
Error responses
When the switcher receives a valid SIS command, it executes the command and sends a 
response to the host device. If the switcher is unable to execute the command because the 
command is invalid or it contains invalid parameters, the switcher returns an error response 
to the host. The error response codes are:
E01 — Invalid input channel number (out of range) 
E06 — Invalid channel change 
E10 — Invalid command 
E13 — Invalid parameter
Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout. 
The command operation is aborted with no other indication.
Using the Command and Response Table
 begins page 22. Symbols are used throughout the 
table to represent variables in the command and response fields. Command and response 
examples are shown throughout the table. The ASCII to HEX conversion table below is for 
use with the command and response table.
ASCII to Hex  Conversion Table
Space