Lexmark 248X ユーザーズマニュアル

ページ / 227
95 
Section 6: Using the Printer Interface
Timing
The following chart shows the timing in microseconds of these signals.
 
31
INIT*
INIT* from the system resets the printer to its initial power-
on-state. The BUSY line goes high, and any received data is 
printed. When INIT* goes low, the printer resets to the power-
on default state. If data is in the USB buffer, the USB FIFO is 
not reset.
32
ERROR*
The printer sets the ERROR* line low if the printer detects an 
error or out-of-paper condition.
A critical error condition exists when both ERROR* and PE 
are low.
33
GND
Ground level.
34-35
Not used.
36
SELECT IN
The printer does not respond to the DC1/DC3 code when this 
signal, 
valid
 
only in Epson mode
, is low.
*   Inverted logic (signal is active when low).
Pin
Line
Description