5   DATA USED FOR POSITIONING CONTROL 
 
5.1.7 Setting items for condition data 
When carrying out "high-level positioning control" or using the JUMP instruction in the 
"major positioning control", the "condition data" must be set as required. The setting 
items for the "condition data" are shown below. 
Up to 10 "condition data" items can be set for each axis. 
Refer to Chapter 10 "High-level Positioning Control" for details on the "high-level 
positioning control", and to Section 5.5 "List of condition data" for details on each 
setting item. 
 
Major positioning 
control 
High-level positioning control 
Control 
 
 
 
Condition data 
Other than 
JUMP 
instruction 
JUMP 
instruction 
Block start 
(Normal 
start ) 
Condition 
start 
Wait start 
Simul-
taneous 
start 
Repeated 
start 
(FOR 
loop) 
Repeated 
start 
(FOR 
condition) 
Da.15
 Condition target 
– 
 
– 
 
 
 
– 
 
Da.16
 Condition operator 
– 
 
– 
 
 
 
– 
 
Da.17
 Address – 
 
– 
 
 
– –   
Da.18
 Parameter 1 
– 
 
– 
 
 
 
– 
 
Da.19
 Parameter 2 
– 
 
– 
 
 
 
– 
 
 
 
 :  Set as required ("–" when not set) 
 
 :  Setting limited 
 
–  :  Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the 
setting range, there is no problem.) 
 
 
 Checking the condition data 
 
Da.15
to
Da.19
are checked with the following timing. 
 
(1)  When the " Block start data" starts 
(2)  When "JUMP instruction" starts 
(3)  When an error check is carried out with GX Configurator-QP