Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
5 - 56 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
5.2.6 OPR detailed parameters 
 
Setting value, setting range 
Setting value buffer memory 
address 
Item 
Value set with peripheral device 
Value set with PLC program 
Default 
value 
Axis 1  Axis 2  Axis 3  Axis 4 
Pr.50
 
Setting for the movement 
amount after near-point dog 
ON 
The setting value range differs depending on the "
Pr.1
 Unit 
setting". 
Here, the value within the [Table 1] range is set. 
 
 [Table 1] on right page
 
80 
81 
230 
231 
380 
381 
530 
531 
0 : 
Pr.9
Acceleration time 0 
1 : 
Pr.25
Acceleration time 1 
2 : 
Pr.26
Acceleration time 2 
Pr.51
 
OPR acceleration time 
selection 
3 : 
Pr.27
Acceleration time 3 
0 82 
232 
382 
532 
0 : 
Pr.10
Deceleration time 0 
1 : 
Pr.28
Deceleration time 1 
2 : 
Pr.29
Deceleration time 2 
Pr.52
 
OPR deceleration time 
selection 
3 : 
Pr.30
Deceleration time 3 
0 83 
233 
383 
533 
 
Pr.50 Setting for the movement amount after near-point dog ON 
 
When using the count method 1) or 2), set the movement amount to the OP after 
the near-point dog signal turns ON. 
(The movement amount after near-point dog ON should be equal to or greater 
than the sum of the "distance covered by the deceleration from the OPR speed to 
the creep speed" and "distance of movement in 10 ms at the OPR speed".)