9 - 15 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
9.1.3 Designating the positioning address 
The following shows the two methods for commanding the position in control using 
positioning data. 
 
 Absolute system 
 
Positioning is carried out to a designated position (absolute address) having the 
OP as a reference.  This address is regarded as the positioning address. (The 
start point can be anywhere.)  
 
Address
100
Address
150
Address
300
100
A point
150
B point
300
C point
Within the stroke limit range
Address 150
Address
100
Address 100
Address 150
OP
(Reference point)
Start point 
End point 
 
Fig. 9.6 Absolute system positioning 
 
 
 Incremental system  
 
The position where the machine is currently stopped is regarded as the start point, 
and positioning is carried out for a designated movement amount in a designated 
movement direction.  
 
Movement amount
+100
Movement
amount -150
Movement amount
-100
Movement amount+50
100
150
300
Movement amount-100
A point
B point
Within the stroke limit range
C point
Movement amount
+100
Movement amount +100
Start point 
End point 
 
Fig. 9.7 Incremental system positioning