Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
9 - 68 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
9.2.12 1-axis speed control 
In "1-axis speed control" ("
Da.2
Control system" = Forward run: speed 1, Reverse 
run: speed 1), control is carried out in the axis direction in which the positioning data 
has been set by continuously outputting pulses for the speed set in "
Da.8
Command 
speed" until the input of a stop command. 
The two types of 1-axis speed control are "Forward run: speed 1" in which the control 
starts in the forward run direction, and "Reverse run: speed 1" in which control starts in 
the reverse run direction. 
 
 Operation chart 
The following chart shows the operation timing for 1-axis speed control with axis 1 
as the reference axis.   
The "in speed control" flag (
Md.31
Status: b0) is turned ON during speed control. 
The "Positioning complete signal" is not turned ON. 
 
t
V
BUSY signal
OFF
ON
Positioning start signal
OFF
ON
Positioning complete signal
OFF
Axis stop signal
(stop command) [Y4] 
OFF
ON
Does not turn ON even 
when control is stopped
by stop command.
OFF
ON
Md.31  Status:b0
In speed control flag
Da. 8  Command speed
[Y10]
[XC]
[X14]
 
 
Fig.9.9 1-axis speed control operation timing