Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
12 - 56 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
12.5.4 Torque change function 
The "torque change function" is used to change the torque limit value during torque 
limiting.  
The torque limit value during torque limiting is normally the value set in the "
Pr.17
 
Torque limit setting value" or "  Cd.101  Torque output setting value" that was 
previously set in the parameters. However, by setting the new torque limit value in the 
axis control data "
Cd.22
 New torque value", and writing it to the QD75MH, the torque 
generated by the servomotor during control can be limited with the new torque value.  
(The "
Cd.22
 New torque value" is validated when written to the QD75MH.)  
 
The details shown below explain about the "torque change function". 
  [1] Control details 
  [2] Precautions during control 
  [3] Setting the torque change function start signal