Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
3 - 21 
MELSEC-Q
 
3   SPECIFICATIONS AND FUNCTIONS 
 
3.4.4 Interface internal circuit 
The outline diagrams of the internal circuits for the QD75MH1 external device 
connection interface are shown below. 
 
(1)   Input 
 
External wiring 
Pin No. 
Internal circuit 
Signal name 
Need for wiring 
1A1 
Upper-limit LS signal 
FLS 
1A2 
Lower-limit LS signal 
RLS 
1A3 
Near-point dog signal 
DOG 
1A4 
Stop signal 
STOP 
1A5 
External command 
signal/switching signal 
CHG 
1A6 
1B7 
Common COM 
1A8 EMI 
1B8 
Forced stop input signal 
EMI. COM 
(+) 
1A19 
PULSER A+ 
(-) 
1B19 
Manual pulse generator 
A phase 
PULSER A- 
(+) 
1A20 
PULSER B+ 
(–) 
1B20 
Manual pulse generator 
B phase 
PULSER B– 
(5V) 
1A15 
(5V) 
1B15 
Manual pulse generator 
power supply (+ 5VDC) 
3,  5 
P5 
(0V) 
1A14 
(0V) 
1B14 
Manual pulse generator 
power supply (GND) 
SG 
 
 
 
 
 
When Upper-limit
switch is not used
When Lower-limit
switch is not used
24VDC
5V
0V
A
B
Manual pulse
generator
(MR-HDP01)
2
 
1A10 
5VDC
 
— — 
— 
1: The symbols in Need for wiring column indicate the following meanings: 
        •    : Wiring is necessary for positioning.       •    : Wiring is necessary depending on the situation. 
2: Either polarity can be connected to the common (COM). 
3: If using separately-placed power supply as manual pulse generator power supply, do not connect power supply 5V(P5) on QD75MH 
side. Use separately-placed power supply as 5V stabilized power supply. Using power supply of different voltage between P5 and SG 
could lead to faults. 
4: When using external input signal of servo amplifier, set "1" with "
 Pr.80 
 External signal selection". In addition, refer to Section 12.4.4 
for wiring of upper/lower limit signal and Section 8.1.1 for wiring of near-point dog signal. 
5: Do not use P5 and SG for other than manual pulse generator power supply.