Mitsubishi Electronics 700 Series ユーザーズマニュアル

ページ / 183
12
Device Map
1.6.2
Internal relay (M) device map
1.6.3
Data register (D) device map
1.6.4
Special relays
The special relays are internal relays with special applications and therefore should
not be switched on-off in the program.
Device No.
Description
M0 to M63
Use freely on user side.
Data 
Register (D)
Inverter Pr. 
Number
Parameter Name
Reference 
Page
D0 to D99
Use freely on user side.
D100 to D119
Pr.506 to 
Pr.515
User parameters. Use freely on user side.
Number
Name
Description
M9008
Self-diagnostic error
Turned on by self-diagnosed error.
M9010
Operation error flag
Turned on by an instruction execution error.
Turned off when error is removed.
M9011
Operation error flag
Turned on by an instruction execution error.
Remains on after normal status is restored.
M9036
Normally ON
M9036 and M9037 are turned on and off independently 
of STOP or RUN.
M9038 and M9039 change depending on the STOP or 
RUN status. In other than the STOP status, M9038 is on 
for one scan only and M9039 is off for one scan only.
M9037
Normally OFF
M9038
On only for 1 scan after 
RUN
M9039
Off only for 1 scan after 
RUN
M9200
Inverter operation status 
control flag (STF)
Control the STF terminal of the inverter from PLC 
function
M9201
Inverter operation status 
control flag (STR)
Control the STR terminal of the inverter from PLC 
function
M9202
Inverter operation status 
control flag (RH)
Control the RH terminal of the inverter from PLC 
function
M9203
Inverter operation status 
control flag (RM)
Control the RM terminal of the inverter from PLC 
function
M9204
Inverter operation status 
control flag (RL)
Control the RL terminal of the inverter from PLC function
M9205
Inverter operation status 
control flag (JOG)
Control the JOG terminal of the inverter from PLC 
function
M9206
Inverter operation status 
control flag (RT)
Control the RT terminal of the inverter from PLC function
M9207
Inverter operation status 
control flag (AU)
Control the AU terminal of the inverter from PLC 
function
M9208
Inverter operation status 
control flag (CS)
Control the CS terminal of the inverter from PLC 
function
M9209
Inverter operation status 
control flag (MRS)
Control the MRS terminal of the inverter from PLC 
function
M9210
Inverter operation status 
control flag (STOP)
Control the STOP terminal of the inverter from PLC 
function