Instructions for the installer
 
 
 
 
 
 
 
 
The standard cable is of the three-core 
3 x 2.5 mm
2
 H07RN-F type. 
For operation from a 400V3N
power 
supply, replace the standard cable with 
one of the H07RN-F type. The cross 
section of the leads of the latter cable 
must not be less than 1.5 mm
2
(5 x 1.5 
mm
2
); the ground (yellow-green) of the
termination to be linked up to the oven 
must be at least 20 mm longer. 
 
 
 
 
If connecting by plug and socket, make sure to use a 25 Amp. three-core 
plug or a 16 Amp. five-core plug in case of operation at 400V3N
. Make 
sure that plug and wall socket are of the same type and are in conformity 
with regulations in force. Also check that the power supply line is 
provided with adequate earthing. Avoid using adapters or shunters. 
 
 
 
In case of permanent connection, ensure that power cable is equipped 
with an easily accessible omnipolar switch fitted in proximity to the 
apparatus and with a gap between contacts equal to or greater than  
3 mm
 
 
 
2.1.1 Safety 
thermostat 
The oven is fitted with a safety device which trips in case of serious 
malfunction. To reset, contact the nearest servicing centre. 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the oven. 
 
 
 
 
 
 
 
 
 