A grounded 3 prong electrical outlet should be located within  
a specified number of inches from the right-hand side 
cabinets or end panel. See the chart following the graphic for 
the number of inches required for your model. For more 
information, see “Electrical Requirements.”
The water shutoff should be located in the base cabinet on 
either side of the refrigerator or some other easily accessible 
area. If the water shutoff valve is not in the cabinets, the 
plumbing for the water line can come through the floor or the 
back wall. See “Water Supply Requirements” for more 
information.
NOTE: Flooring under refrigerator must be at same level as the 
room. Face of cabinetry must be plumb. 
Electrical Requirements
Before you move your refrigerator into its final location, it is 
important to make sure you have the proper electrical 
connection.
Recommended Grounding Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp fused, grounded 
electrical supply is required. It is recommended that a separate 
circuit serving only your refrigerator be provided. Use an outlet 
that cannot be turned off by a switch. Do not use an 
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground 
Fault Circuit Interrupter) protected outlet, nuisance tripping of the 
power supply may occur, resulting in loss of cooling. Food quality 
and flavor may be affected. If nuisance tripping has occurred, 
and if the condition of the food appears poor, dispose of it. 
NOTE: Before performing any type of installation, cleaning, or 
removing a light bulb, remove the top grille and turn the master 
power switch to OFF or disconnect power at the circuit breaker 
box. 
When you are finished, turn ON the master power switch or 
reconnect power at the circuit breaker box. Then reset the control 
to the desired setting. 
Model
Width A 
(as shown 
above)
Width A for 
Overlay Models 
(as shown above)
Dimension B 
(as shown 
above)
36
35
¹⁄₂" to 35³⁄₄" 
(90.2 cm to 
90.8 cm) 
35
³⁄₄" to 36" 
(90.8 cm to 
91.4 cm)
4" (10.2 cm)
42
41
¹⁄₂" to 41³⁄₄" 
(105.4 cm to 
106 cm)
41
³⁄₄" to 42" 
(106 cm to 
106.7 cm)
10" (25.4 cm)
48
47
¹⁄₂" to 47³⁄₄" 
(120.7 cm to 
121.3 cm)
47
³⁄₄" to 48" 
(121.3 cm to 
121.9 cm)
16" (40.6 cm)
80" - 90"
(203-229 cm) 
6"
(15.2 cm)
83
¹⁄₂
" (212.1 cm) min.
84
³⁄₄
" (215 cm) max.
to bottom of solid soffit
24"
(60.96 cm) min. 
1"
(2.54 cm) 
77"
(196 cm)
6"
(15.2 cm)
6"
(15.2 cm)
A
Width
(see chart following)
B
Dimension
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING