NI 5412 Specifications
Markers
Table 8.  
Specification
Value
Comments
Destinations
1. PFI<0..1> (SMB front panel connectors)
2. NI PXI-5412—PXI_Trig<0..6> (backplane connector) 
NI PCI-5412—RTSI<0..6>
Quantity
One Marker per Segment.
Quantum
Marker position must be placed at an integer multiple of 
four samples.
Width
>150 ns. Refer to t
m2
 at NI Signal Generators Help»
Devices»NI 5412»NI <bus>-5412»Waveform 
Generation»Marker Events
.
Skew
Destination
With Respect to Analog 
Output
Refer to t
m1
 at 
NI Signal 
Generators 
Help»Devices»
NI 5412»
NI <bus>-5412»
Waveform 
Generation»
Marker Events
.
PFI<0..1>
±2 Sample Clock Periods
NI PXI-5412
PXI_Trig<0..6>
NI PCI-5412 RTSI<0..6>
±2 Sample Clock Periods