4.1.6
 
Electronic circuit board thermal protection 
The appliance is equipped with a device which constantly measures the 
temperature of the electronic circuit board. 
If the temperature should exceed preset values, the device will trigger 
specific functions to reduce the temperature and allow the ceramic hob to 
keep operating correctly. 
The following table lists the automatically triggered procedures and the 
relative trigger temperature: 
 
 
Operation
 
Trigger 
temperature
 
Fan switches on at low speed
 
50 °C
 
Fan switches on at high speed
 
60 °C
 
Fan switches back to low speed 
55 °C
 
Fan switches off
 
45 °C
 
Operating power is reduced from Power function to 9
 
76 °C
 
Operating power is reduced by one point for each 
cooking zone
 
85 °C
 
All cooking zones switch off
 
90 °C
 
Cooking zones switch back on at reduced power
 
85 °C
 
All cooking zones return to normal operation
 
80 °C
 
The power displays on the hob flash to signal all operations of this kind. 
 
4.1.7
 
Ceramic hob thermal protection 
Each cooking zone is equipped with a device which constantly measures 
its temperature.  
If the temperature should exceed preset values, the device will trigger 
specific functions to reduce the temperature and allow the ceramic hob to 
keep operating correctly. 
The following table lists the automatically triggered procedures and the 
relative trigger temperature: 
Operation
 
Trigger 
temperature
 
Operating power is reduced from Power function to 9
 
250 °C
 
Operating power is reduced by one point
 
280 °C
 
Cooking zone switches off 
300 °C
 
Power returns to set value
 
250 °C
 
The power displays on the hob flash to signal all operations of this kind.