2.3.6 Inspection 
WARNING 
Before starting maintenance and/or inspection, turn off the power and wait for 15 
minutes or more until the charge lamp turns off. Then, confirm that the voltage 
between P( ) and N( ) is safe with a voltage tester and others. Otherwise, an 
electric shock may occur. In addition, always confirm from the front of the servo 
amplifier, whether the charge lamp is off or not. 
To avoid the risk of electric shock, only qualified personnel should attempt 
inspections. For repair, contact your local sales office. 
 
 
CAUTION 
 
Do not disassemble and/or repair the equipment on customer side. 
 
 
It is recommended to make the following checks periodically. 
 
(a)  Check the direct drive motor bearings, etc. for unusual noise. 
 
(b)  Check the cables and the like for scratches and cracks. Especially when the junction cable is movable, 
perform periodic inspection according to operating conditions. 
 
(c)  Check the direct drive motor rotor (output shaft) and coupling for misalignment. 
 
(d)  Check the power supply connector and encoder connector tightening for looseness. 
 
2.3.7 Life 
The following parts must be replaced periodically as listed below. If any part is found faulty, it must be replaced 
immediately even when it has not yet reached the end of its life, which depends on the operating method and 
environmental conditions. For parts replacement, please contact your local sales office. 
 
Parts name 
Guideline of life 
Remarks 
Bearings 
20,000 to 30,000 hours 
Encoder 
20,000 to 30,000 hours 
Absolute position 
storage unit (option) 
20,000 to 30,000 hours 
Battery MR-J3BAT 
(option) 
5,000 hours 
(battery life with power off) 
The Guideline of Life field gives the reference time. If any fault is found 
before this time is reached, the parts must be replaced. 
 
When the direct drive motor is run at rated speed under rated load, bearings should be exchanged in 20,000 to 
30,000 hours as a guideline. This differs on the operating conditions. The bearings must also be replaced if 