4.6.2
Parameter list
·  indicates simple mode parameters.
· The abbreviations in the explanations below indicate:
...V/F control
...Advanced magnetic flux vector control
...Real sensorless vector control
...vector control. 
(Parameters without any indication are valid for all control)
  
Func
tion
Parameter
Name
Incre
ments
Initial 
Value
Range
Description
Re
la
te
d
 
p
a
ra
me
te
rs
M
a
nual t
o
rque b
o
ost
0

Torque boost
0.1%
3/2% 
0 to 30%
Set the output voltage at 0Hz as %.
* The initial value differs according to the inverter
capacity. (7.5K or lower
 / 11K or higher)
46
Second torque boost
0.1%
9999
0 to 30%
Set the torque boost when the RT signal is on.
9999
Without second torque boost
112
Third torque boost
0.1%
9999
0 to 30%
Set the torque boost when the X9 signal is on.
9999
Without third torque boost
Maxim
u
m/
minim
u
fr
equency
1

Maximum frequency
0.01Hz
120Hz 0 to 120Hz Set the upper limit of the output frequency.
2

Minimum frequency
0.01Hz
0Hz
0 to 120Hz Set the lower limit of the output frequency.
18
High speed maximum 
frequency
0.01Hz
120Hz 120 to 400Hz
Set when performing the operation at 120Hz or 
more. 
Bas
e f
requenc
y,
 volt
age
3

Base frequency
0.01Hz
60Hz
0 to 400Hz
Set the frequency when the motor rated torque is 
generated. (50Hz/60Hz)
19
Base frequency voltage
0.1V
9999
0 to 1000V
Set the base voltage.
8888
95% of power supply voltage
9999
Same as power supply voltage
47
Second V/F (base 
frequency)
0.01Hz
9999
0 to 400Hz
Set the base frequency when the RT signal is on.
9999
Second V/F is invalid
113
Third V/F (base frequency)
0.01Hz
9999
0 to 400Hz
Set the base frequency when the X9 signal is ON.
9999
Third V/F is invalid
Mult
i-
speed set
ting operat
ion
4

Multi-speed setting (high 
speed)
0.01Hz
60Hz
0 to 400Hz Set frequency when the RH signal is on.
5

Multi-speed setting (middle 
speed)
0.01Hz
30Hz
0 to 400Hz
Set frequency when the RM signal is on.
6

Multi-speed setting (low 
speed)
0.01Hz
10Hz
0 to 400Hz
Set frequency when the RL signal is on.
24
27
Multi-speed setting (4 
speed to 7 speed)
0.01Hz
9999
0 to 400Hz,
9999
Frequency from 4 speed to 15 speed can be set 
according to the combination of the RH, RM, RL and 
REX signals.
9999: not selected
232
239
Multi-speed setting (8 
speed to 15 speed)
0.01Hz
9999
0 to 400Hz,
9999
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
V/FV/FV/F
V/FV/FV/F
to
to