Event Reporting and U-Abort Capabilities
Issue  7 May 1998
3-9
Alerting Event Report
ECS sends the Alerting Event Report for monitored, controlled, and 
domain-controlled calls when the following events occur: 
When the destination of a call is an on-ECS station and ringing or zip tone 
is started.
When a call is redirected to an off-ECS station and the ISDN ALERTing 
message is received from an ISDN-PRI facility.
When a switch-classified call is trying to reach an off-ECS station, and the 
call classifier detects either precise, imprecise, or special ringing.
When a switch-classified or user-classified call is placed to an off-ECS 
station, and the ALERTing message is received from the ISDN-PRI facility.
NOTE:
When a classifier and an ISDN-PRI facility both report alerting on a 
switch-classified call, then the first occurrence generates an Alerting 
Event Report; succeeding reports are not reported by ECS.
Consecutive Alerting Event Reports are possible in the following cases:
A station is alerted first and the call goes to coverage; an Alerting Event 
Report is generated each time a new station is alerted.
A principal and its bridging users are alerted; an Alerting Event Report is 
generated for the principal and for each bridged station alerted.
A call is alerting a Terminating Extension Group (TEG); one report is sent 
for each TEG member alerted.
A call is alerting a Personal Central Office Line (PCOL); tone report is sent 
for each PCOL member alerted.
A call is alerting a coverage/answer point; one report is sent for each 
alerting member of the coverage answer group.
A call is alerting a principal with SAC active; one report is sent for the 
principal and one or more are sent for the coverage points.
The Alerting Event Report is 
not sent
 for calls that connect to announcements as 
a result of ACD split forced announcement or announcement vector commands.
When an ASAI-monitored call reaches a converse vector step, the ALERTing 
message sent to the ASAI host will include an optional cause (CS3/23) to inform 