Unnecessary service calls may be expensive, frustrating and time consuming. Before you call for service, please review the potential problems, possible 
causes and remedies shown in the table below.
Troubleshooting
Problem
1. Nothing works.
*
2. Ignitors do not spark.
*
3. Sparking but no flame.
4. Burners ignite but flame is extremely large, 
distorted or yellow.
5. Burner flame goes out at low setting.
6. Ignitors spark continuously after flame 
ignition.
Possible Cause
Grill is not connected to electrical power.
Power supply is not energized.
Circuit breaker is tripped.
House fuse is blown.
Gas shut-off valve is in “off” position.
Ports on U-burner are clogged or dirty.
Ports on U-burner are clogged or dirty.
Grill is being operated on wrong type of gas.
Regulator is not installed, is faulty, or is set for 
the wrong type of gas.
Low gas pressure.
Air intake holes under the control panel are 
obstructed.
Incorrect installation.
Ports on U-burner are clogged or dirty at ignition 
location.
Power supply polarity is reversed.
Ignitors are wet or dirty.
Low burner flame.
Remedy
Have grill connected to the proper electrical 
supply by a qualified electrician or appliance 
installer.
Check circuit breaker, wiring, fuses, plugs, etc.
Reset circuit breaker.
Replace house fuse.
Turn shut-off valve to “on” position.
Brush U-burner with a steel brush and clear 
blockage with a toothpick or metal object 
(straightened paper clip, needle, or wire).
Brush U-burner with a steel brush and clear 
blockage with a toothpick or metal object 
(straightened paper clip, needle, or wire).
Ensure that the type of grill matches the gas 
supply (natural gas or LP).
Check installation, replace regulator, or set 
regulator for proper gas type.
Contact gas company, have incoming gas 
pressure tested.
Remove obstruction.
Check installation dimensions against 
installation instructions.
Brush U-burner with a steel brush and clear 
blockage with a toothpick or metal object 
(straightened paper clip, needle, or wire).
Have polarity corrected.
Dry ignitors or clean ignitors with a metal brush 
to remove any residue.
Contact gas company, have incoming gas 
pressure tested.
Troubleshooting Guide
*   The grill burners can be manually ignited with a match or the hand spark ignitor supplied with the unit. (Refer to Manual Lighting section 
on page 6.)