Mitsubishi Electronics E60 ユーザーズマニュアル

ページ / 415
2. MACHINING 
PARAMETERS 
2.1 Process 
Parameters 
II - 3 
 
2. MACHINING 
PARAMETERS 
The number of digits in the decimal section of the parameters related to length is determined by the input setting 
unit. 
The input setting unit is set with parameter "#1003 iunit". 
Input setting unit 
No. of digits in decimal section 
Example of setting range 
0 to 999.999 (mm) 
0 to 99.9999 (mm) 
 
 
2.1 Process 
Parameters 
<WRK COUNT> (No. of workpieces machined) 
Item 
Contents 
Setup range (unit) 
8001  WRK COUNT M 
Set the M code that counts the No. of workpiece 
repeated machining. 
The No. will not be counted when set to 0. 
0 to 99 
8002  WRK COUNT 
The current machining No. is displayed. Set the 
initial value. 
0 to 999999 
8003  WRK LIMIT 
Set the maximum No. of workpieces machined. 
A signal is output to PLC when the No. of machining 
times is counted to this limit. 
0 to 999999 
 
<AUTO TLM> (Automatic tool length measurement)  
Item 
Contents 
Setup range (unit) 
8004  SPEED 
Set the feedrate during automatic tool length 
measurement. 
1 to 60000 (mm/min) 
8005  ZONE r 
Set the distance between the measurement position 
and deceleration start point. 
0 to 99999.999 (mm) 
8006  ZONE d 
Set the tolerable zone of the measurement position.
If the sensor signal turns ON in front of d before the 
measurement position‚ or if the signal does not turn 
ON after d is passed‚ an alarm will occur. 
0 to 99999.999 (mm) 
 
<AUTO CORNER OVR> (Automatic corner override)  
Item 
Contents 
Setup range (unit) 
8007  OVERRIDE 
Set the override value for automatic corner override. 0 to 100 (%) 
8008  MAX ANGLE 
Set the max. corner opening angle where 
deceleration should start automatically.  
If the angle is larger than this value‚ deceleration will 
not start. 
0 to 180 (°) 
8009  DSC. ZONE 
Set the position where deceleration starts at the 
corner. 
Designate at which length point before the corner 
deceleration should start. 
0 to 99999.999 (mm)