Mitsubishi Electronics E68 ユーザーズマニュアル

ページ / 415
5. 
BASE SPECIFICATIONS PARAMETERS 
 
II - 22 
 
5.  BASE SPECIFICATIONS PARAMETERS 
After setting up the parameter (PR) listed in the table, turn OFF the NC power.  To validate the parameter, 
turn ON the power again. 
(SETUP PARAM 1. 1/16) 
Items 
Details 
Setting range (unit) 
1001 
(PR) 
SYS_ON System 
validation 
setup 
Specify the existence of the NC axis and PLC axis 
with 1 or 0. 
0:  Not used 
1:  Used 
1002 
(PR) 
axisno Number 
of 
axes 
Set the number of NC axes and PLC axes. 
With E68, specify 4 as the maximum value for the 
NC axis and 2 as that for the PLC axis so that the 
total of those values is 6 or less. 
With E60, specify 3 as the maximum value for the 
NC axis and 2 as that for the PLC axis so that the 
total of those values is 5 or less. 
0 to 4 
1003 
(PR) 
iunit Input 
setup 
unit 
Specify the input setting unit for the NC axis and 
PLC axis. The parameter units will follow this. 
B:   1 
µ
C:   0.1 
µ
1013  axname 
Axis name
Specify each axis’ name address with an alphabetic 
character. 
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C. 
Do not specify the same address. 
The PLC address does not need to be set. (The axis 
name is displayed as 1 and 2.) 
Axis addresses such as 
X, Y, Z, U, V, W, A, B, 
and C 
1014 incax 
Increment 
command 
axis name
When specifying the program movement rate’s 
absolute or incremental method with an address‚ 
specify the incremental command axis name 
address with an alphabetic character.  
The address that can be used is the same as #1013 
axname.  
Specify an address that is different from that #1013.  
Setting is not required if absolute/incremental 
specification with addresses is not performed 
(#1076 Abslnc = 0). 
 
1015 
(PR) 
cunit Command 
unit 
Specify the minimum unit of the program movement 
amount.  
cunit  Movement amount for movement command 1
0:  #1003 iunit is followed. 
1:  0.0001mm (0.1
µm) 
10:  0.001mm (   1 
µm)  
If there is a decimal point in the movement 
command‚ the decimal point position will be handled 
as 1mm regardless of this setting. 
 
0 #1003 
iunit 
0.1 
µ
10 
1  
µ
1016 
(PR) 
iout 
Inch output  Specify whether the machine system (ball screw 
pitch‚ position detection unit) is an inch unit system 
or metric unit system. 
0:  Metric unit 
     system 
1:  Inch unit system