10. PLC 
CONSTANTS 
10.1 PLC 
Timer 
II - 298 
 
10. PLC CONSTANTS 
10.1 PLC Timer 
(SETUP PARAM 6. 1/14) to (SETUP PARAM 6. 2/14) 
PLC device 
Item 
Details 
Setting range 
6000 
 
 
 
 
6015 
T000 
 
 
 
 
T015 
10ms adding 
timer <10ms> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set to 
"0". 
0 to 32767 (
×10ms) 
6016 
 
 
 
 
6095 
T016 
 
 
 
 
T095 
100ms adding 
timer <10ms> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set to 
"0". 
0 to 32767 (
×100ms)
6096 
 
 
 
 
6103 
T096 
 
 
 
 
T103 
100ms 
cumulative 
timer 
<100ms INC> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set to 
"0". 
0 to 32767 (
×100ms)
 
(SETUP PARAM 6. 10/14) to (SETUP PARAM 6. 14/14) 
PLC device 
Item 
Details 
Setting range 
6600 
 
 
 
 
6999 
R1200/bit0 
R1250/bit0 
 
 
 
R1224/bitF 
R1274/bitF 
PLC timer 
expansion 
 
 
10ms adding 
timer 
<10ms> 
Set the time for the expanded PLC timer
This is set for the timer coils: R1200 to 
R1224, and timer contacts: R1250 to 
R1274. 
A timer command can be issued to a 
contact other than the existing timer 
contacts (T0 to T103, Q0 to Q151). 
0 to 32767 (
×10ms) 
 
10.2 PLC Counter 
(SETUP PARAM 6. 3/14) 
PLC device 
Item 
Details 
Setting range 
6200 
 
 
 
 
6223 
C000 
 
 
 
 
C023 
Counter 
Set the time for the counter used in the 
PLC program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit1" in the 
following "[BIT SELECT]" is set to 
"0". 
0 to 32767