Mitsubishi Electronics C64 ユーザーズマニュアル

ページ / 317
8.  Spindle Parameters 
8.1  Spindle Base Specifications Parameters 
 
174 
8.  Spindle Parameters
 
 
8.1  Spindle Base Specifications Parameters 
 
For parameters indicated with a (PR) in the table, turn the NC power OFF after setting. The setting is 
validated after the power is turned ON again. 
 
No. Items 
Details 
Setting range 
(Unit) 
3001 
3002 
3003 
3004 
slimit 1 
 2 
 3 
 4 
Limit rotation 
speed 
Set spindle rotation speed for maximum motor 
rotation speed with gears 00, 01, 10, 11. 
(Set the spindle rotation speed for the S analog 
output 10V.) 
3005 
3006 
3007 
3008 
smax 1 
 2 
 3 
 4 
Maximum 
rotation speed 
Set maximum spindle speed with gears 00, 01, 
10, 11. 
Set the value that is equal to or larger than "slimit" 
value. 
By comparing the S command value of gear 1 to 
4, a spindle gear shift command will be output 
automatically. 
0 to 99999 (r/min)
3009 
3010 
3011 
3012 
ssift 1 
 2 
 3 
 4 
Shift rotation 
speed 
Set spindle rotation speed for gear shifting with 
gears 00, 01, 10, 11. 
(Note) Setting too large value may cause a gear 
nicks when changing gears. 
0 to 32767 (r/min)
 
3013 
3014 
3015 
3016 
stap 1 
 2 
 3 
 4 
Tap rotation 
speed 
Set maximum spindle rotation speed during tap 
cycle with gears 00, 01, 10, 11. 
0 to 99999 (r/min)
 
3017 
3018 
3019 
3020 
stapt 1 
 2 
 3 
 4 
Tap time 
constant 
Set time constants for constant inclination 
synchronized tapping for gears 00, 01, 10, 11 
(linear acceleration/deceleration pattern). 
1 to 5000 (ms)