VR8104, VR8204 AND VR8304 INTERMITTENT PILOT COMBINATION GAS CONTROLS
69-1225—4
4
Corrosive Chemicals
Corrosive chemicals can attack the control, eventually 
causing a failure. If chemicals are used for routine 
cleaning, avoid contact with the control. Where 
chemicals are suspended in air, as in some industrial or 
agricultural applications, protect the control with an 
enclosure.
Dust or Grease Accumulation
Heavy accumulations of dust or grease can cause the 
control to malfunction. Where dust or grease can be a 
problem, provide covers for the control to limit 
contamination.
Heat
Excessively high temperatures can damage the control. 
Make sure the maximum ambient temperature at the 
control does not exceed the rating of the control. If the 
appliance operates at very high temperatures, use 
insulation, shielding, and air circulation, as necessary, to 
protect the control. Proper insulation or shielding should 
be provided by the appliance manufacturer; verify proper 
air circulation is maintained when the appliance is 
installed.
INSTALLATION
When Installing this Product...
1.
Read these instructions carefully. Failure to follow 
them could damage the product or cause a 
hazardous condition.
2.
Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.
3.
Installer must be a trained, experienced service 
technician.
4.
After installation is complete, check out product 
operation as provided in these instructions.
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury 
or death.
Follow these warnings exactly:
1. Disconnect power supply before wiring to 
prevent electrical shock or equipment damage.
2. To avoid dangerous accumulation of fuel gas, 
turn off the gas supply at the appliance service 
valve before starting installation, and perform 
Gas Leak Test after installation is complete.
3. Do not bend pilot tubing at gas control or pilot 
burner after compression fitting is tightened, or 
gas leakage at the connection can result.
4. Always install a sediment trap in the gas 
supply line to prevent contamination of the gas 
control.
5. Do not force the gas control knob. Use only 
your hand to turn the gas control knob. Never 
use any tools. If the gas control knob will not 
operate by hand, the gas control should be 
replaced by a qualified service technician. 
Force or attempted repair may result in fire or 
explosion.
CAUTION
Equipment Damage.
Can burn out valve coil terminals.
Never apply a jumper across (or short) the valve 
coil terminals, even temporarily.
Follow the appliance manufacturers instructions if 
available; otherwise, use these instructions as a guide.
IMPORTANT
These gas controls are shipped with protective 
seals over the inlet and outlet tappings. Do not 
remove the seals until ready to install adapters 
or connect the piping.
Converting Gas Control from Natural Gas 
to LP Gas (or LP Gas to Natural Gas)
WARNING
Fire Or Explosion Hazard.
Can cause property damage, severe injury 
or death.
1. Do not attempt to convert step-opening models 
(suffix letter P). 
2. Always change the main and pilot burner 
orifices when converting from natural to LP gas 
or from LP to natural gas. Carefully follow 
appliance manufacturer specifications and 
instructions to assure proper appliance 
conversion.
3. Gas controls are factory-set for natural (and 
manufactured) or LP gas. Do not attempt to 
use a gas control set for natural 
(manufactured) gas on LP gas, or a gas control 
set for LP gas on natural (manufactured) gas.
Controls with standard, slow-opening, and two-stage 
regulators (model numbers with suffix H, K, M, or Q) can 
be converted from one gas to the other with a conversion 
kit (ordered separately). See Table 4 for the correct 
conversion kit.
Convertible Pressure Regulators
Controls with suffix letter R are convertible pressure 
regulator models. They can be converted from natural 
gas to LP gas or from LP gas to natural gas without a 
conversion kit. 
Before converting the control from one gas to another, 
check the control label and the appliance manufacturer’s 
rating plate to determine if the pressure regulator setting 
(factory set) will meet the appliance manifold 
requirements after conversion.
NOTE:
Convertible pressure regulator models (suffix 
letter R) do not have field-adjustable regulators.
If the factory pressure regulator setting meets the 
appliance manifold requirement, convert the control as 
follows:
1.
Remove the pressure regulator cap, Fig. 1.
2.
Invert the cap so that the letters appear that 
represent the gas type appropriate for the 
appliance. NAT for natural manufactured gas, LP 
for liquid petroleum gas.
3.
Replace the cap and tighten firmly.