Mitsumi electronic -1 ユーザーズマニュアル

ページ / 40
29
3-3. OPERATIONAL FREQUENCY RANGE
b) Correct the LEV separately by temperature difference “ ∆RT” between main/sub indoor coil thermistor.
∆RT (°F/°C)
LEV opening
correction (pulse)
10.8/6   ∆RT
2
7.2/4  ∆RT < 10.8/6
1
∆RT < 7.2/4
1
In addition, decrease the target discharge temperature corresponding ∆RT.
∆ RT (°F/°C)
Temperature to be 
decreased (°F/°C)
10.8/6   ∆RT
18/10
7.2/4   ∆RT< 10.8/6
9/5
∆RT < 7.2/4
9/5
MXZ-2A20NA
Number of operating 
unit 
Capacity code 
COOL (Hz) 
DRY (Hz) 
HEAT (Hz) 
Min. Max. 
Min. Max. 
Defrost 
1
4
20
65
25
48
92
92
7
20
85
30
48
92
92
9,10 20
100
75
48
100
100
12
20
100
75
48
100
100
2
8 ~ 10 
30
105
52
58
112
100
11 ~ 13 
30
105
52
58
112
100
14 ~ 16 
30
105
52
58
112
100
17 ~ 
20
105
100
58
112
100
MXZ-2A20NA-
1
Number of operating 
unit 
Capacity code 
COOL (Hz) 
DRY (Hz) 
HEAT (Hz) 
Min. Max. 
Min. Max. 
Defrost 
1
4
20
65
35
48
92
92
7
20
85
34
48
92
92
9,10 20
93
75
48
92
92
12
20
93
75
48
92
92
2
8 ~ 10 
30
93
52
58
110
101
11 ~ 13 
30
93
52
58
110
101
14 ~ 16 
30
93
52
58
110
101
17 ~ 
30
93
93
58
110
101
MXZ-2A20NA-
2
Number of operating 
unit 
Capacity code 
COOL (Hz) 
DRY (Hz) 
HEAT (Hz) 
Min. Max. 
Min. Max. 
Defrost 
1
4
20
65
25
30
92
92
7
20
85
34
30
92
92
9,10 20
93
75
30
92
92
12
20
93
75
30
92
92
2
8 ~ 10 
40
93
53
58
112
100
11 ~ 13 
40
93
53
58
112
100
14 ~ 16 
40
93
53
58
112
100
17 ~ 
40
93
93
58
112
100