Bunn Ultra-2 ユーザーズマニュアル

ページ / 14
3
INTRODUCTION
This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls 
are accessible only through password protection.
CONTENTS
Introduction & Warranty ................................................................................................ 3
Site Preparation, Electrical Requirements ...................................................................... 3
Initial Setup .................................................................................................................... 4
Operating Controls ......................................................................................................... 8
Using the Dispenser for Granita-Type Products ........................................................... 10
Using the Dispenser for Cold Liquid Products ............................................................. 10
Other Recommendations For Your Dispenser .............................................................. 11
Recommended Daily Cleaning ..................................................................................... 12
User Notices ................................................................................................................ 14
40563 041108
SITE PREPARATION
 
The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is 
for indoor use only.
 
The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter 
removal, and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides 
and the wall or another appliance. The dispenser performs better if not placed near any heating appliance. Leave 
some space so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS
CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service 
as specified below.
Model ULTRA-1 & 2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch 
circuit rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
(Refer to the dataplate for exact electrical requirements.)
Model ULTRA-1A & 2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual 
branch circuit rated 230 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical require-
ments.)
Model ULTRA-1B & 2B, This dispenser has an attached cordset and requires a 2-wire, grounded, individual 
branch circuit rated 100 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical require-
ments.)
NOTE – Bunn-O-Matic does not recommend the use of any extension cord with these dispensers.