42
J-300 
12.8  Winterizing
Your Jacuzzi spa is designed to automatically protect itself against 
freezing when operating properly. During periods of severe freezing 
temperatures, you should check periodically to be certain that the 
electrical supply to the spa has not been interrupted. 
In extreme, bitter 
cold weather less than 32°F (0°C), program the primary filtration 
If you do not intend to use your spa, or if there is a prolonged power 
outage during periods of severe freezing temperatures, 
it is important 
that all water be removed from the spa and equipment to protect 
against damage from freezing.
Expert winterization of your spa is highly recommended, contact 
your authorized Jacuzzi dealer. In emergency situations, damage can 
be 
minimized by taking the following steps:
CAUTION: TURN OFF POWER TO HOT TUB!
1.  Turn off power to the spa.
3.  Turn the massage/diverter selector(s) into the middle combo position 
4.  Turn the waterfall valve(s) to the open position to allow the water in 
5.  Open all the air controls and leave them open until you resume use 
6.  As the water level drops below the seats, use whatever means 
necessary to get the water out of the recessed seating areas and 
into the footwell, such as a wet/dry vacuum.
7.  When the water level ceases to drop, use whatever means available 
to remove any remaining water from the foot well, such as a wet/dry 
vacuum.
8.  Remove the synthetic cabinet panel under the control panel and 
locate the drain plugs on the front of the pump(s), (Figure A, page 
heater.
Note: Approximately one to two gallons will be released during this 
procedure. Use a wet/dry vacuum or other means to keep this from 
flooding the equipment compartment. Replace the drain plugs.
9.   Loosen the hose clamp on the circulation pump intake behind the 
control box (Figure A, page 16) and pull the hose off (twist hose 
back and forth while pulling outward). Tip hose down and allow to 
drain, then reinstall hose and clamp.
10. Loosen hose clamp at bottom of CLEAR
RAY® system and pull hose 
off of CLEAR
RAY fitting (twist the hose back and forth while pulling 
downward). Tip hose down and allow to drain. Then reinstall hose 
and clamp. Remove the cover of the CLEAR
RAY system to access 
the UV bulb and quartz tube. Remove and store the UV bulb in a