Marantz PD4201 ユーザーズマニュアル

ページ / 49
  PDxx01  
       RS-232C Control Specification                                                      Page: 9 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-4. 
VOLUME Gain Data 
Function 
The external control equipment changes the VOLUME gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER SOUND Gain Flag     
 
05H 
 
DATA01: VOLUME Gain Flag   
 
 
01H 
 
DATA02: VOLUME Gain   
 
 
00H: Step0 
  
 
 
 
 
 
 
0AH: Step10 (Default) 
  
 
 
  
 
2AH: 
Step42 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER SOUND Gain Flag     
 
05H 
 
DATA01: VOLUME Gain Flag 
 
 
01H 
 
 5-5. 
AUDIO Mute ON 
Function 
The external control equipment switches on AUDIO Mute of the plasma monitor. 
 
Transmission Data 
  9FH  80H  60H  3EH  00H  CKS 
ACK 
  3FH  60H  80H  3EH  00H  CKS 
 
 5-6. 
AUDIO Mute OFF 
Function 
The external control equipment switches off AUDIO Mute of the plasma monitor. 
 
Transmission Data 
  9FH  80H  60H  3FH  00H  CKS 
ACK 