Rotel RB-1091 オーナーマニュアル

ページ / 52
8
Troubleshooting
Most difficulties in audio systems are the result of 
poor or wrong connections, or improper control 
settings. If you encounter problems, isolate the 
area of the difficulty, check the control settings, 
determine the cause of the fault and make the 
necessary changes. If you are unable to get 
sound from the RB-1091, refer to the sugges-
tions for the following conditions:
Front Panel Power Indicator Is 
Not Lit
No main power to the RB-1091. Check AC 
power connections at the amplifier and the 
AC outlet. Check the front panel power switch. 
Make sure that it is set to the ON position. If 
using 12V trigger power-on, make sure that 
a trigger signal is present at rear panel 12V 
TRIG IN jack.
No Sound
If the amp is getting AC power, but is producing 
no sound, check the PROTECTION INDICATOR 
on the front panel. If lit, see below. If not, check 
all of your connections and control settings on 
associated components. Make sure that your 
input connections and speaker connections 
match your system configuration.
Protection Indicator Is Lit
The front panel PROTECTION INDICATOR 
will light when the RB-1091 protection circuits 
have shut off the amplifier. Typically, this oc-
curs only when the amplifier has overheated, 
when there is faulty speaker wiring, or after 
a period of extreme use. Turn off the system 
and wait for the amp to cool. Then push the 
front panel power switch in and out to reset 
the protection devices. If the problem is not 
corrected or reoccurs, there is a problem with 
the system or the amplifier itself.
RB-1091 Mono Power Amplifier
Specifications
Power Configurations 
1 x 500 Watts
Watts/Channel 
500 watts, with 20KHz filter, 8 ohm load,  
 
 
 
20-20 kHz, 0.03% THD
Total Harmonic Distortion (20Hz-20kHz, 8 ohms) 
 
Continuous Rated Power 
< 0.03% 
 
One-Half Rated Power 
< 0.03% 
 
One Watt per Channel 
< 0.03%
Power Output (4 Ohms, 0.09% THD) 
1000 watts
Output Peak Current 
40A
Intermodulation Distortion 60 Hz:7 kHz, 4:1 
< 0.03%
Damping Factor (8 ohms) 
400
Amp Gain 
27.2dB
Input Sensitivity/Impedance 
2.2 V / 11.1 k ohms
Frequency Response 
10 - 40 KHz (±3dB)
Signal to Noise Ratio (IHF A) 
118 dB
Power Requirements 
 
USA 
120 Volts, 60 Hz 
 
Europe  
230 Volts, 50 Hz
Power Consumption 
300 Watts 
 
 
 
34 Watts - Idling 
 
 
 
3 Watts - Standby
Dimensions (W x H x D) 
432 x 92 x 407 mm 
 
 
 
17
1
/
8
 x 3
5
/
8
 x 16
1
/
8
 in
Panel Height (for rack mounting) 
80 mm, 3
1
/
8
 in
Weight (net) 
7.8 kg, 17.2 lb.
All specifications are accurate at the time of printing.  