Biasing the Flexi-50 For Different Tubes 
Power Tubes 
One of the Flexi’s most exciting features is that you can very easily re-bias the amplifier 
for new power tubes—either of the same type, or of different types.  The Flexi can be 
used with 6L6, EL-34, 6V6, 6CA7, 8417, 6550, KT-66, KT-77, KT-88, KT-90, KT-100, 
EL-84 (with Yellow Jacket adaptor), 6K6, 6F6, and any other derivations of the above 
tube types.  You can even mix and match different tube types together, eliminating the 
need for matched pairs! 
 
Re-biasing the Flexi is simple.  You’ll need a digital multi-meter, and then just follow the 
directions below: 
 
 
 
1. With tubes installed, power up the Flexi.  Leave it in standby until the tubes have 
heated up (at least 1 minute for most tubes, 2 minutes for 6550, KT-88, KT-90 and KT-
100 tube types).  
  
2.  Insert the black probe of multi-meter into the black socket (A)
 
3.  Insert the red probe into the red socket for Tube 1 (B)