Hussmann innovator インストール手順

ページ / 27
6. Rock the door out and pull the bottom hinge
pin out from the bottom socket.
7. Install the new door in reverse order.
8. Adjust the torque on the new door. If needed,
adjust sag.
REPLACING DOOR HINGE SPRING 
The door must be removed before replacing the
door hinge spring. 
Pull the hinge spring assembly out of the bottom
of the door and replace with a new assembly. See
Figure 8. Note that there are right-hand and left-
hand hinge spring assemblies. 
REPLACING MAGNETIC GASKET 
Carefully remove the old gasket from the groove
in the back of the door, Figure 9.
The new gasket will be easier to work with if it is
at ambient temperature. Begin by lubricating the
new gasket with a mild soap and water solution. 
Innovator Door Installation and
Service Instruction
P/N 0425683F
5
HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483  U.S.A. • WWW.HUSSMANN.COM
Figure 8. Replacing Door Hinge 
Spring Assembly
Figure 9. Removing Door Gasket
Gasket