Frigidaire fra053pu1 ユーザーガイド

ページ / 13
11
2009 Electrolux Home Products, Inc.
All rights reserved.
(continued)
Operating Instructions, CARE & CLEANING
ADDITIONAL THINGS 
YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in 
your control that you should become familiar with. 
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug 
the unit before cleaning to prevent shock or fire hazards. 
The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned 
off and on quickly. This prevents overheating of the compressor and possible circuit 
breaker tripping. The fan will continue to run during this time. 
The control will maintain the set temperature within 2 °F, between 62 °F  and 
86 °F (17 °C and 30 °C).
There is a 2-Second delay for the compressor shutting down when selecting 
FAN ONLY/HEAT. This is to cover the possibility of having to roll through to select 
another mode.
After a power outage, the unit will memorize the last setting and return the unit to 
the same setting once power is restored.
CARE & CLEANING
This unit has two filters, they are filter A and B. Grasp the upper panel tab and 
take off the filter A which behind the grill of the back panel (Fig.24). Remove the 
lower filter B by loosening the screws. Take down the air inlet grille, then remove 
the air filter as shown in Fig.25 & 26.
Air Filter Cleaning
Wash the filter using liquid dishwashing detergent and warm water. Rinse filter 
thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly 
dry before replacing. 
Or, instead of washing you may vacuum the filter clean.
If you plan to store the appliance during the winter, cover it with plastic or return
it to its carton.
Winter Storage
Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet 
and front may be dusted with an oil-free cloth or washed with a cloth dampened 
in a solution of warm water and mild liquid dishwashing detergent. Rinse 
thoroughly and wipe dry.
Cabinet Cleaning
Never use harsh cleaners, wax or polish on the cabinet front.
Be sure to wring excess water from the cloth before wiping around the controls. 
Excess water in or around the controls may cause damage to the air conditioner.
Fig. 24
Filter A
Filter B
Fig. 25
Fig. 26
Remove three 
screws and
take the air 
intake grille
down
Operating Instructions
The control is capable of displaying temperature in degrees Fahrenheit or degrees 
Celsius. To convert from one to the other and back, press and hold the "TEMP" 
Up (     ) and Down (    ) buttons together for 3 seconds.
Remove the filter B 
out from the grille