Do This First
(for existing sleeve)
Note that the air conditioner dimensions are: 24
"
wide,
14
1
2
"
high, and 18
1
2
"
deep (without front). Install Air
Conditioner according to these installation instructions
to achieve the best performance. Save these installation
instructions for future reference.
Items in Kit
You may not need all parts in the kit. Discard unused
parts.
Qty.
Tapered Spacer Blocks 17
"
Long 2
Centering/Support Blocks 4
1
2
"
x 3
1
2
"
x 1
1
2
2
Plastic Divider 1/8” x 4
1
2
"
x 14
1
2
1
Stuffer Seal 1
"
x 1
1
"x 84
1
Seal 1
1
2
"
x 1
1
2
"
x 26
1
2
2
Seal 1
1
2
"
x 1
1
2
"
x 14
2
Seal 1
1
2
"
x 3/8
"
x 26
1
2
2
Seal 1
1
2
"
x 3/8
"
x 14
2
Seal 1” x 3/4
"
x 14
1
Trim Frame (side legs) 2
Trim Frame (top & bottom legs) 2
Ground Wire (green) 1
Nut for grounding screw 1
Grounding Screw 1
Grille (plastic) 1
Nuts (plastic) 4
Screw w/washer 4
How to Install
1. Identify the wall-sleeve brand for your installation,
from the chart below.
Brand
Wall Sleeve Dimensions
(inches)
Width
Height
Depth
White-Westinghouse
Frigidaire 25
1
15
1
16, 17
1
2
Carrier (52F Series)     
}
or 22
General Electric/
Hotpoint 26 15
5
16
7
8
Whirlpool 25
7
16
1
17
1
8
or 23
Fedders/Emerson 27 16
3
16
3
4
or 19
3
4
Sears/Kenmore 25
3
16
7
18
5
8
Emerson/Fedders 26
3
15
3
15
Carrier (51S Series) 25
3
16
7
18
5
8
Friedrich 27 16
3
16
3
4
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition and
have a rear grille that securely attaches to sleeve, or
rear flange that serves as a stop for the Air Conditioner.
CAUTION: When installation is complete, replacement
unit MUST have a rearward
slope as shown.
2. Remove old Air Conditioner from wall sleeve and
prepare wall sleeve as follows:
— Clean interior (do not disturb seals).
— Wall sleeve must be securely fastened in wall before
installing Air Conditioner. Drive more nails or screws
through sleeve, into wall, if needed.
— Repair paint if needed.
3. If not existing, drill a 3/16
"
clearance hole for ground-
ing screw through left side of wall sleeve, in a clear area
about 3 inches maximum (to suit) back from front edge
of sleeve as shown below. Next attach ground wire
inside sleeve, using grounding screw and nut. Pull loose
end of ground wire out front of sleeve, and temporarily
bend it down and around lower edge of sleeve.
Wall sleeve to unit
sleeve grounding
4. Prepare the wall sleeve for installation of the new unit
per the following Brand instructions.
#1 Emerson 15
"
Deep
#2 Fedders 19
3
4
"
Deep
#3 Fedders or Friedrich 16
3
4
"
Deep
#4 General Electric/Hotpoint 16
7
8
"
Deep
#5 Sears or Carrier (51S Series) 18
5
8
"
Deep
#6 Whirlpool 17
1
8
"
Deep
#7 Whirlpool 23
"
Deep
#8 White-Westinghouse/Frigidaire/ 16
"
+ 17
1
2
"
Deep
Carrier (52F Series)
#9 White-Westinghouse/Frigidaire 22
"
Deep
5. Install new unit into wall sleeve.
6. To attach ground wire to the new unit, remove the
screw from the left side front.
7. Assemble and install the
Trim Frame (see instruction).
P/N  66121627
REAR
UNIT
FRONT
LEVEL
1/4” to 5/16”
Wa l l
S l e e v e
3"
Max.
3
/
16"
Hole
1"
8,000-12,000 BTU TTW
Installation Instructions:
1