1. 
Make sure you have all the necessary parts.
Installation kit contents:
3/8"Screws (4)
End Cap &
Leveling Leg (1)
Fig. 1A Installation Hardware Model 463AAC008BA 
 Nuts(2)
 Fig. A  Installation Hardware
Washers(2)
1"Screws (2)
Support 
platform(1) 
Support angles (1) 
Speed clips(2) 
Filler panel(1) 
Sliders(2) 
Seals (2)
Shorter 
seal (1)
7/16" Screws(2)
Top retainer (1)
Foam (1)
2. 
Choose a proper sized window, as shown right.
15-1/2 inches minimum width
17-1/2 inches maximum width (for casement 
    windows)
21-1/4 inches minimum height (with window 
   panel retainer)
20-5/16  inches  minimum   height   (window 
   panel retainer removed)
40 inches maximum height
NOTE: 
Height  measurement must be of a clear
opening  above mounting platform. In some cases,
due  to  a  variety  of  stop and track arrangements, 
the    above    dimensions    may   vary   slightly.   If 
necessary, installation can be made by alternating
window   jambs.  (See    Alternate   Window   Jamb
Applications.)
(continued)
 
3. 
Choose the proper window location
Choose a window that allows the cooled air to flow
freely and directly into room(s) you wish to cool.
Remember, it is difficult to move air around corners.
Fig. 3
Awning
Side
obstruction
Ground
Fence,
wall, or
other
obstacle.
12" Min.
30" Min.
20" 
Min.
20" 
Min.
As shown below:
20      inches
minimum
height
40 inches
maximum
height
5
16
15      inches
minimum
width
1
2
17      inches
maximum
width
(Casement
window)
1
2
 3